Item type |
紀要論文(ELS) / Departmental Bulletin Paper(1) |
公開日 |
2007-01-01 |
タイトル |
|
|
タイトル |
Development of a Modified Apparatus for Hand Dexterity Evaluation : interrater and test-retest reliability |
|
言語 |
en |
言語 |
|
|
言語 |
eng |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
hand dexterity |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
modified apparatus |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
interrater reliability |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
test-retest reliability |
資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
departmental bulletin paper |
ID登録 |
|
|
ID登録 |
10.15112/00005071 |
|
ID登録タイプ |
JaLC |
ページ属性 |
|
|
内容記述タイプ |
Other |
|
内容記述 |
P(論文) |
著者名(英) |
Fukui, Takeshi
Inoue, Keiko
Tsunehisa, Kentarou
Furukawa, Hiroshi
|
著者所属(英) |
|
|
|
en |
|
|
Department of Rehabilitation, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare |
著者所属(英) |
|
|
|
en |
|
|
Department of Rehabilitation, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare |
著者所属(英) |
|
|
|
en |
|
|
Faculty of Occupational Therapy, Kawasaki Junior College of Rehabilitation |
著者所属(英) |
|
|
|
en |
|
|
Faculty of Health Sciences, Kobe University School of Medicine |
抄録(英) |
|
|
|
en |
|
|
Objectives: Hand dexterity encompasses three basic elements: spacing, grading and timing. However, no evaluation method simultaneously addresses all three elements. In 1998, development of a new apparatus was begun, and an initial prototype was completed in 1999. In a previous study, it was noted that the apparatus needed improvement. Modifications were initiated in 2003, and completed in 2004. Interrater reliability and test-retest reliability of this modified apparatus were examined. Subjects and Methods: Twenty-seven healthy subjects participated in the study. Of the total of 54 hands, three were excluded from the study due to data deficiency. All subjects were evaluated simultaneously by two faculty researchers to determine interrater reliability, and then reevaluated by the same researchers about one week later to determine test-retest reliability. Results: The results for interrater reliability showed significant reliability for grading and timing, but not spacing. In test-retest reliability, significant reliability was found for timing, but not spacing and grading. Conclusions: This study indicated that the modified apparatus was not completely reliable. This is consistent with the difference in relative difficulty of each element. It is important that time intervals are set based on the subjects' abilities. At the same time, it is necessary to initiate clinical studies which include actual patients in the sample. |
書誌情報 |
en : Kawasaki journal of medical welfare
巻 12,
号 2,
p. 61-67,
発行日 2007
|
公開者 |
|
|
出版者 |
川崎医療福祉学会 |
雑誌書誌ID |
|
|
収録物識別子タイプ |
NCID |
|
収録物識別子 |
AA11108172 |
ISSN |
|
|
収録物識別子タイプ |
PISSN |
|
収録物識別子 |
1341-5077 |
URL |
|
|
内容記述タイプ |
Other |
|
内容記述 |
http://www.kawasaki-m.ac.jp/soc/mw/journal/en/2007-e12-2/07_fukui.pdf |