  1. Kawasaki journal of medical welfare
  2. Vol.5
  3. No.1

<Original Paper>Gait Endurance Index for Patients with Hemiplegia due to Cerebrovascular Accidents

https://doi.org/10.15112/00000207
https://doi.org/10.15112/00000207
1e2f011b-dee6-43c0-b1e7-42ac6222b6e4
名前 / ファイル ライセンス アクション
KJ00000039018.pdf PDF (574.4 kB)
Item type 紀要論文(ELS) / Departmental Bulletin Paper(1)
公開日 1999-01-01
タイトル
タイトル <Original Paper>Gait Endurance Index for Patients with Hemiplegia due to Cerebrovascular Accidents
言語 en
言語
言語 eng
キーワード
言語 en
主題Scheme Other
主題 gait endurance
キーワード
言語 en
主題Scheme Other
主題 hemiplegia
キーワード
言語 en
主題Scheme Other
主題 cerebrovascular accident
キーワード
言語 en
主題Scheme Other
主題 index
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
ID登録
ID登録 10.15112/00000207
ID登録タイプ JaLC
ページ属性
内容記述タイプ Other
内容記述 P(論文)
著者名(英) WATANABE, Susumu

× WATANABE, Susumu

en WATANABE, Susumu

Search repository
KUNIYASU, Katsushi

× KUNIYASU, Katsushi

en KUNIYASU, Katsushi

Search repository
著者所属(英)
en
Department of Restorative Science, Faculty of Medical Professions Kawasaki University of Medical Welfare
著者所属(英)
en
Department of Restorative Science, Faculty of Medical Professions Kawasaki University of Medical Welfare
抄録(英)
en
The purpose of this study was to investigate the validity of the gait endurance index ( GEI ) for easily evaluating the physical fitness of hemiplegic patients. The subjects were 52 hemiplegic patients( 39 men and 13 women, 55.1�}11.3 years old) and 11 healthy subjects ( 7 men and 4 women, 64.0�}6.1 years old) as a control group. All patients were able to walk indoors without aids or with a brace or cane or both. All subjects were tested using the GEI, which was defined as the gait distance for 5 min. / recovery heart rate. The recovery heart rate was defined as the total number of heart beats during the 1-1.5 min., 2-2.5 min. and 3-3.5 min. intervals just after gait. Oxygen uptake and heart rate were measured with portable equipment during gait in 13 hemiplegics who volunteered to participate and the 11 healthy subjects. The gait distance for 5 min., recovery heart rate and GEI were measured twice in 23 patients during a two week period. The gait distance of the patients was significantly shorter than that of the healthy subjects, but there was no significant difference in the recovery heart rate between the two groups. The GEI of the patients was significantly smaller than that of the healthy subjects. A significant correlation was found between the gait distance for 5 mm. and oxygen uptake in the volunteer group, and between the recovery heart rate and the steady state heart rate during gait. No correlation between the recovery heart rate and the gait distance for 5 min. was found, in either the patients or the control group. These results indicate that the GEI is a valid and simple measure of physical fitness for hemiplegic patients after strokes.
書誌情報 en : Kawasaki journal of medical welfare

巻 5, 号 1, p. 7-13, 発行日 1999
公開者
出版者 川崎医療福祉学会
雑誌書誌ID
収録物識別子タイプ NCID
収録物識別子 AA11108172
ISSN
収録物識別子タイプ PISSN
収録物識別子 1341-5077
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-19 10:22:58.261684
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3