WEKO3
アイテム
Use of electrical or magnetic stimulation for generating hip flexion torque.
https://kwmw.repo.nii.ac.jp/records/13627
https://kwmw.repo.nii.ac.jp/records/13627569b2c1f-9afa-4b8a-aa16-99a235c29f89
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
|
![]() |
|
|
![]() |
|
|
![]() |
|
|
![]() |
|
|
![]() |
|
|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2014-10-01 | |||||||||||
タイトル | ||||||||||||
タイトル | Use of electrical or magnetic stimulation for generating hip flexion torque. | |||||||||||
言語 | en | |||||||||||
言語 | ||||||||||||
言語 | eng | |||||||||||
キーワード | ||||||||||||
主題Scheme | Other | |||||||||||
主題 | 磁気刺激 | |||||||||||
キーワード | ||||||||||||
主題Scheme | Other | |||||||||||
主題 | 経皮的電気刺激 | |||||||||||
キーワード | ||||||||||||
主題Scheme | Other | |||||||||||
主題 | トルク | |||||||||||
キーワード | ||||||||||||
主題Scheme | Other | |||||||||||
主題 | 痛み | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | Magnetic Stimulation | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | Transcutaneous Electrical Stimulation | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | Torque | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | Pain | |||||||||||
資源タイプ | ||||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||
資源タイプ | journal article | |||||||||||
ページ属性 | ||||||||||||
内容記述タイプ | Other | |||||||||||
内容記述 | P(論文) | |||||||||||
著者名(英) |
Ito, Tomotaka
× Ito, Tomotaka
× Tsubahara, Akio
× Watanabe, Susumu
|
|||||||||||
著者所属(英) | ||||||||||||
en | ||||||||||||
Department of Rehabilitation, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare | ||||||||||||
著者所属(英) | ||||||||||||
en | ||||||||||||
Department of Rehabilitation Medicine, Kawasaki Medical School | ||||||||||||
抄録(英) | ||||||||||||
en | ||||||||||||
Objective: The purpose of this study was to investigate the most suitable site and method to effectively generate isometric hip flexion torque (torque value) using transcutaneous electrical or magnetic stimulation. Design:Eleven healthy volunteers underwent torque value and pain degree measurements during magnetic stimulation of the iliopsoas using three coil placements. After that, the peak torque values generated under three conditions of electrical stimulation of the sartorius, the tensor fasciae latae, and the rectus femoris or that generated by magnetic stimulation of the iliopsoas were recorded at maximum tolerance intensity. Results: No significant differences in torque values were observed among the 3 coil placements.Magnetic stimulation of a point below the inguinal ligament caused significantly more pain than the otherpoints. Magnetic stimulation of the iliopsoas generated significantly higher torque values than electrical stimulation of the 2 hip flexor muscles together. Conclusions: The hip joint was one of the most suitable regions for application of magnetic stimulation,as an alternative method to electrical stimulation. |
||||||||||||
書誌情報 |
en : American journal of physical medicine & rehabilitation 巻 92, 号 9, p. 755-761, 発行日 2013 |
|||||||||||
公開者 | ||||||||||||
出版者 | Author | |||||||||||
ISSN | ||||||||||||
収録物識別子タイプ | ISSN | |||||||||||
収録物識別子 | 1537-7385 | |||||||||||
書誌レコードID | ||||||||||||
収録物識別子タイプ | NCID | |||||||||||
収録物識別子 | AA12538858 | |||||||||||
PubMed番号 | ||||||||||||
関連タイプ | isVersionOf | |||||||||||
識別子タイプ | PMID | |||||||||||
関連識別子 | 23370583 | |||||||||||
DOI | ||||||||||||
関連タイプ | isVersionOf | |||||||||||
識別子タイプ | DOI | |||||||||||
関連識別子 | 10.1097/PHM.0b013e318282c643 | |||||||||||
著者版フラグ | ||||||||||||
出版タイプ | AM | |||||||||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa |