WEKO3
アイテム
Effects of Ankle Braces on Ground Reaction Force and Electromyography during Landing Movement
https://doi.org/10.15112/00010826
https://doi.org/10.15112/00010826a25f0c0a-d2d7-4ff9-a92f-99c30b4ffeb1
| 名前 / ファイル | ライセンス | アクション |
|---|---|---|
|
|
|
| Item type | 紀要論文(ELS) / Departmental Bulletin Paper(1) | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 公開日 | 2013-01-01 | |||||||||
| タイトル | ||||||||||
| タイトル | Effects of Ankle Braces on Ground Reaction Force and Electromyography during Landing Movement | |||||||||
| 言語 | en | |||||||||
| 言語 | ||||||||||
| 言語 | eng | |||||||||
| キーワード | ||||||||||
| 言語 | en | |||||||||
| 主題Scheme | Other | |||||||||
| 主題 | ground reaction force | |||||||||
| キーワード | ||||||||||
| 言語 | en | |||||||||
| 主題Scheme | Other | |||||||||
| 主題 | electromyograms | |||||||||
| キーワード | ||||||||||
| 言語 | en | |||||||||
| 主題Scheme | Other | |||||||||
| 主題 | ankle braces | |||||||||
| 資源タイプ | ||||||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||
| 資源タイプ | departmental bulletin paper | |||||||||
| ID登録 | ||||||||||
| ID登録 | 10.15112/00010826 | |||||||||
| ID登録タイプ | JaLC | |||||||||
| item_1_description_1 | ||||||||||
| 内容記述タイプ | Other | |||||||||
| 内容記述 | P(論文) | |||||||||
| 著者名(英) |
Tsuchida, Yasuki
× Tsuchida, Yasuki
× Miyakawa, Takeshi
|
|||||||||
| 著者所属(英) | ||||||||||
| en | ||||||||||
| Master's Program in Health and Sports Science, Graduate School of Health Science and Technology, Kawasaki University of Medical Welfare | ||||||||||
| 著者所属(英) | ||||||||||
| en | ||||||||||
| Department of Health and Sports Science, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare | ||||||||||
| item_1_textarea_12 | ||||||||||
| en | ||||||||||
| The purpose of this study was to verify the effect of a new style of ankle brace on ground reaction force (GRF) and electromyography (EMG) during landing movement. Two conditions were set, 1 with a brace and 1 without. And physical tasks measured were landing movement from a 30 cm and 50 cm height in both conditions. Without a brace, the GRF condition at the 30 cm was significantly lower than at 50 cm (p<0.05). On EMG of interior head of gastrocnemius muscle at 50 cm, the condition of wearing a brace was significantly lower than without (p<0.05). This brace possibly makes the angle of the ankles pronate and supinate limitarily. | ||||||||||
| 記事種別(英) | ||||||||||
| 内容記述タイプ | Other | |||||||||
| 内容記述 | Short Report | |||||||||
| bibliographic_information |
en : Kawasaki journal of medical welfare 巻 19, 号 1, p. 13-16, 発行日 2013 |
|||||||||
| item_1_publisher_23 | ||||||||||
| 出版者 | 川崎医療福祉学会 | |||||||||
| item_1_source_id_13 | ||||||||||
| 収録物識別子タイプ | NCID | |||||||||
| 収録物識別子 | AA11108172 | |||||||||
| item_1_source_id_19 | ||||||||||
| 収録物識別子タイプ | PISSN | |||||||||
| 収録物識別子 | 1341-5077 | |||||||||
| item_1_description_17 | ||||||||||
| 内容記述タイプ | Other | |||||||||
| 内容記述 | http://www.kawasaki-m.ac.jp/soc/mw/journal/en/2013-e19-1/P13-16_tsuchida.pdf | |||||||||