{"created":"2023-06-19T10:05:13.297354+00:00","id":14593,"links":{},"metadata":{"_buckets":{"deposit":"81997005-1829-4e9b-9120-790dd79205b1"},"_deposit":{"created_by":20,"id":"14593","owners":[20],"pid":{"revision_id":0,"type":"depid","value":"14593"},"status":"published"},"_oai":{"id":"oai:kwmw.repo.nii.ac.jp:00014593","sets":["7:287:301"]},"author_link":["64193","64194"],"item_1_alternative_title_20":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Case Study of the Precision of the Display Values of Several Activity Monitors at Jogging"}]},"item_1_biblio_info_14":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1-2","bibliographicPageEnd":"303","bibliographicPageStart":"295","bibliographicVolumeNumber":"28","bibliographic_titles":[{"bibliographic_title":"川崎医療福祉学会誌"}]}]},"item_1_creator_6":{"attribute_name":"著者名(日)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"文谷, 知明"}],"nameIdentifiers":[{"nameIdentifier":"64193","nameIdentifierScheme":"WEKO"}]}]},"item_1_description_1":{"attribute_name":"ページ属性","attribute_value_mlt":[{"subitem_description":"P(論文)","subitem_description_type":"Other"}]},"item_1_description_2":{"attribute_name":"記事種別(日)","attribute_value_mlt":[{"subitem_description":"症例報告/事例報告","subitem_description_type":"Other"}]},"item_1_full_name_7":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"64194","nameIdentifierScheme":"WEKO"}],"names":[{"name":"BUNYA, Tomoaki"}]}]},"item_1_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.15112/00014534","subitem_identifier_reg_type":"JaLC"}]},"item_1_publisher_23":{"attribute_name":"公開者","attribute_value_mlt":[{"subitem_publisher":"川崎医療福祉学会"}]},"item_1_source_id_13":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AN10375470","subitem_source_identifier_type":"NCID"}]},"item_1_source_id_19":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0917-4605","subitem_source_identifier_type":"ISSN"}]},"item_1_text_22":{"attribute_name":"その他(別言語)の雑誌名","attribute_value_mlt":[{"subitem_text_value":"Kawasaki medical welfare journal"}]},"item_1_text_9":{"attribute_name":"著者所属(日)","attribute_value_mlt":[{"subitem_text_value":"川崎医療福祉大学 医療福祉学部 健康体育学科"}]},"item_1_textarea_11":{"attribute_name":"抄録(日)","attribute_value_mlt":[{"subitem_textarea_value":"本研究の目的は,同じ機種の活動量計4個を異なる4部位(ハーフパンツの右ポケット,左ポケット,左胸ポケット,首から垂らす)に装着して運動を行い,その表示値(歩数,運動量,距離)の精度を検証することであった.被験者は健康な50歳代の男性1名である.活動量計には5社(A,B,C,D,E)の機器を用いた.運動は屋外における約7.6kmのジョギングとした.その結果,本被験者のジョギングにおいては,E社の活動量計が歩数,運動量,距離の全てにおいて,いずれの部位に装着しても精度が高いことが示唆された."}]},"item_1_textarea_12":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_textarea_language":"en","subitem_textarea_value":"The purpose of this study was to investigate the precision of the display value (number of steps, energy expenditure except rest and distance) when exercising by placing four of the same activity monitors at four different positions (shorts right pocket, shorts left pocket, left breast pocket and hanging from the neck). The subject was one healthy man in his 50s. Activity monitors of five manufacturers (A, B, C, D and E) were used. The exercise was approximately 7.6 km jogging outdoors. As a result, regarding the jogging of this subject, it was suggested that number of steps, energy expenditure except rest and distance used by activity monitor of manufacturer E are high precision, no matter where it is placed."}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-03-05"}],"displaytype":"detail","filename":"16_文谷知明.pdf","filesize":[{"value":"772.6 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"PDF","url":"https://kwmw.repo.nii.ac.jp/record/14593/files/16_文谷知明.pdf"},"version_id":"bd2d5f58-7859-4cb9-bebd-b50ec4e4c020"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"activity monitor","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"jogging","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"precision","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"case study","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"ジョギング時における数種類の活動量計表示値の精度に関する事例検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"ジョギング時における数種類の活動量計表示値の精度に関する事例検討"}]},"item_type_id":"1","owner":"20","path":["301"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-03-05"},"publish_date":"2019-03-05","publish_status":"0","recid":"14593","relation_version_is_last":true,"title":["ジョギング時における数種類の活動量計表示値の精度に関する事例検討"],"weko_creator_id":"20","weko_shared_id":20},"updated":"2023-06-19T10:30:31.530183+00:00"}